Changing the Label Extraction Conditions
Set the label extraction conditions. You can select to extract only labels that satisfy all four of the following:
Number of labels, specified area, gravity X, and gravity Y conditions.
[Inspect] [Inspection] [Labeling] [Modify] [Settings] Details [Details] Tab Page
[Meas. Parameter] [Extraction condition]
1 Press and set each of the parameters
for the extraction conditions.
Parameter Setting Description
Number of labels Range: 1 to 100
Default: 100
Set the maximum number of labels to
detect.
Area
Range: 0 to 999,999,999.9999
Defaults: Upper limit: 999,999,999.9999
Lower limit: 0
Specify the area range to judge as a
label.
Gravity X
Range: 99,999,999.9999 to 999,999,999.999
Defaults:
Upper limit: 999,999,999.999,
Lower limit: 999,999,999.9999
Specify the gravity X position to judge as
a label.
Gravity Y
Range: 999,999,999.9999 to 999,999,999.999
Defaults:
Upper limit: 999,999,999.999,
Lower limit: 999,999,999.9999
Specify the gravity Y position to judge as
a label.