EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspecting with the Labeling Inspection Item
FQ2-S/CH User’s Manual
321
4
Setting Up Inspections
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or
used in calculations.
4-18 Calculations and Judgments Using Inspection Item Data p. 323
Expression
text string
Data name Description Data range
JG Judgement
2: No judgement
(not measured)
0: Judgement is OK
1: Judgement is NG
13: Teaching not performed error
14: Figure not registered error
15: Out of range error
This is the Labeling judgement results.
L Number of labels 0 to 100 This is the number of labels found.
TAR Total label area 0 to 999,999,999.9999 This is the total area of all labels found.
AR[0] to
AR[99]
Area 0 to 999,999,999.9999 These are the areas of each individual
label.
X[0] to X[99] Gravity X 99,999.9999 to 99,999.9999
99,999.9999 to 99,999.9999
These are the X coordinates of the center
of each label.
Y[0] to Y[99] Gravity Y 99,999.9999 to 99,999.9999 These are the Y coordinates of the center
of each label.
ATH[0] to
ATH[99]
Master angle 180 to 180 These are the master angle of the center
of each label.
SA Reference area 0 to 999,999,999.9999 This is the reference area.
SX Ref. position X
(reference position X)
99,999.9999 to 99,999.9999 This is the X coordinate of the reference
position.
SY Ref. position Y
(reference position Y)
99,999.9999 to 99,999.9999 This is the Y coordinate of the reference
position.

Table of Contents