Inspecting with the Edge Pitch Inspection Item
292
FQ2-S/CH User’s Manual
Measurement Data That Can Be Logged for Edge Pitch
The following values can be logged as measurement data.
* When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392
Errors
Edge Not Found
The measured edge pitch will be 0. Perform the following.
• If a color was specified, make sure the color of the measurement object has not changed from the specified color.
• Set the color again if necessary.
• If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page is cor-
rect.
Edge level: p. 276
Measured item Range of value Description
Judgement
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
This is the judgement result from the measurements.
Edge pitch 0 to 999 This is the number of objects that were detected.
Average pitch 0 to 99999.9999 This is the average pitch that was detected.
Max. pitch 0 to 99999.9999 This is the maximum pitch that was detected.
Min. pitch 0 to 99999.9999 This is the minimum pitch that was detected.
Average width 0 to 99999.9999 This is the average width that was detected between edges.
Max. width 0 to 99999.9999 This is the maximum width that was detected between
edges.
Min. width 0 to 99999.9999 This is the minimum width that was detected between
edges.