Mounting to a Control Panel
The Touch Finder can be mounted on a panel using the FQ-XPM Panel Mounting Adapter.
Always turn OFF the Touch Finder power before attaching or detaching the Panel Mount Adapter.
Attaching or detaching with the power turned ON may cause a failure.
Installation Procedure
1 Set the Touch Finder in the Panel Mount
Adapter.
2 Press the slider up on the Touch Finder.
3 Create holes in the panel for mounting.
Refer to the following page for hole dimensions.
Dimensions: p.562
4 Connect the cable to the Touch Finder.
5 Mount the Touch Finder with the Panel Mount
Adapter from the front of the panel.
6 Hook the hooks on the Mounting Bracket in
the four holes of the Panel Mount Adapter and
secure them with screws.
(Tightening torque: 1.2 N·m)
7
Check that the Touch Finder is attached prop-
erly to the Panel.
Important
Mounting
Bracket

Table of Contents