Inspecting with the Search Inspection Item
224
FQ2-S/CH User’s Manual
Increasing Processing Speed
The following two methods can be used to reduce processing time.
Reduce the range in which a search is performed for the model.
Changing the measurement region: p. 227
Reduce the angle range setting.
Adjust the [Angle range] parameter to reduce the range in which a search for the model is performed.
Setting the angle range: p. 222
Increase the [Candidate level] value and limit the models.
Select the Results to Output: p. 221
Editing the Model and Measurement Regions
This section describes how to edit the following regions.
If the model region is changed, perform teaching again. p. 217
Measurement region
(region that is searched for the model)
Model registration region
Important

Table of Contents