Setting Up Ethernet
FQ2-S/CH User’s Manual
67
2
Installation and Connections
2-6 Setting Up Ethernet
FQ2-S1
FQ2-S2
FQ2-S3 FQ2-S4
FQ2-CH
Connecting to Sensors from the Touch Finder
Configurations Consisting of Only Sensors and the Touch Finder
When only Sensors and a Touch Finder are used, IP addresses are automatically assigned.
No settings are required to use Ethernet.
Connections on Existing Networks
If a Sensor or Touch Finder is connected to a network where a PLC or computer is already connected, the
Ethernet settings must be made compatible with the existing network.
Set the IP addresses with one of the following methods.
Sensor
(Setup Mode) [Sensor settings] [Network] [Ethernet] [IP address setting]
1 Press [Fixed].
2 Set the IP address and subnet mask according to the network settings.
TouchFinder
(Setup Mode) [TF settings] [Ethernet] [AUTO]
1 Press [OFF].
2 Set the IP address and subnet mask according to the network settings.
If you connect the Touch Finder or PC Tool to a Sensor on a different network through a router, set fixed IP
addresses.
When connecting by EtherNet/IP or PROFINET, set fixed IP addresses for the Sensors.
Note