Setting Up Inspections
Specify the Verification String with Direct Input
[Inspect] − [Inspection] − [Add item.] − [OCR] − [Settings] Tab Page
[Item ref.]: Select this item to use the immediately preceding read results as the verification character
string.
The following inspection items can be used as references.
FQ2-S4 Series: Bar code, 2D-code, 2D-code (DPM), and OCR
FQ2-CH Series: OCR
You cannot reference an inspection item that is after the current inspection item. After a char-
acter string is registered, a reference item number, such as “Ref. 00,” will be displayed to the
right of the character string in the master data.
1 Touch [Verification].
2 Touch [Matching Mode],
and then select [Direct Input].
3 Touch [Master data regist.].
4 Touch the master data to register.
5 You can use any of the following three methods to register character strings in the master
data from the menu display.
[Auto]: A character string is read from an image and registered in the master data.
The procedure is essentially the same as the procedure for teaching in step 2.
[Manual]: A character string is entered directly in the master data.
Select this menu when making a change to the master data registered using [Auto]
menu.
You can use a software keyboard to register a character string with up to 32 characters.
You can set letters, numbers, symbols, and the following wildcards: * and ?.
• *: A wildcard for a character string of 0 or more characters
• ?: A wildcard for one character (alphabetic or numeric)
Note