EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reading with OCR
FQ2-S/CH User’s Manual
149
4
Setting Up Inspections
Specify the Verification String with Direct Input
[Inspect] [Inspection] [Add item.] [OCR] [Settings] Tab Page
[Item ref.]: Select this item to use the immediately preceding read results as the verification character
string.
The following inspection items can be used as references.
FQ2-S4 Series: Bar code, 2D-code, 2D-code (DPM), and OCR
FQ2-CH Series: OCR
You cannot reference an inspection item that is after the current inspection item. After a char-
acter string is registered, a reference item number, such as “Ref. 00,” will be displayed to the
right of the character string in the master data.
1 Touch [Verification].
2 Touch [Matching Mode],
and then select [Direct Input].
3 Touch [Master data regist.].
4 Touch the master data to register.
5 You can use any of the following three methods to register character strings in the master
data from the menu display.
[Auto]: A character string is read from an image and registered in the master data.
The procedure is essentially the same as the procedure for teaching in step 2.
[Manual]: A character string is entered directly in the master data.
Select this menu when making a change to the master data registered using [Auto]
menu.
You can use a software keyboard to register a character string with up to 32 characters.
You can set letters, numbers, symbols, and the following wildcards: * and ?.
*: A wildcard for a character string of 0 or more characters
?: A wildcard for one character (alphabetic or numeric)
Note

Table of Contents