Inspecting with the Search Inspection Item
218
FQ2-S/CH User’s Manual
Step 3 Adjusting Judgement Parameters
[Inspect] − [Inspection] − [Add item.] − [Search] − [Settings] Tab Page
1 Press [Judgement].
2 Press each parameter and set the range that is to be
judged as OK. Set the range for each of the following
parameters.
Continuous measurements will be performed for the im-
ages that are taken.
3 Press [OK] to accept the value.
4 Press [Back] to end making the setting.
Parameter Setting Description
Correlation
Range: 0 to 100
Defaults: Lower: 60
Upper: 100
Adjust the upper and lower limits of the correlation for
an OK judgment.
Position X
Range: −99,999.9999 to 99,999.9999
Defaults: Lower: −99,999.9999
Upper: 99,999.9999
Adjust the upper and lower limits of measurement
position X for an OK judgment.
Position Y
Range: −99,999.9999 to 99,999.9999
Defaults: Lower: −99,999.9999
Upper: 99,999.9999
Adjust the upper and lower limits of measurement
position Y for an OK judgment.
Angle
Range: −180 to 180 (Default)
Defaults: Lower: −180
Upper: 180
Adjust the upper and lower limits of angle for an OK
judgment.
Count
Range: 0 to 32
Defaults: Lower: 0
Upper: 32
Adjust the upper and lower limits of the detection count
for an OK judgment.
Blue for OK. Red for NG.
Upper limit Lower limit
If more than one result was detected, you
can switch to a display for each result.
(Multi-point output must be enabled.)
You can change the parameters for judgement conditions on the
Display Settings Display.
Press
[ ] − [Display setting] on the right of the display to switch
to the Display Settings Display.