Inspecting with the Sensitive Search Inspection Item
262
FQ2-S/CH User’s Manual
Step 3 Adjusting Judgement Parameters
[Inspect] [Inspection] [Add item.] [Sensitive Search] [Settings] Tab Page
1 Press [Judgement].
2 Press each parameter and set the range that is to be
judged as OK. Set the range for each of the following
parameters.
Continuous measurements will be performed for the im-
ages that are taken.
3 Press [OK] to accept the value.
4 Press [Back] to end making the setting.
Lower limit
Blue for OK. Red for NG.
Upper limit
You can change the parameters for judgment conditions on the
Display Settings Display.
Press [
] [Display setting] on the right of the display to switch
to the Display Settings Display.
Note