Adjusting the Judgment Parameters
348
FQ2-S/CH User’s Manual
There are no judgment condition settings for the following inspection items.
• Bar code and 2D-code (FQ2-S4 series only)
• Labelling and Edge pitch (FQ2-S1/S2/S3/S4 series only)
[] − [Select the method.] on the right side of the display
You can select one of the following three patterns as the judgment method.
1) Threshold (minimum): The lower limit of the variations between OK object is used as the judgment
condition.
2) Threshold (average): The median value between the OK object variations and NG object variations is
used as the judgement condition.
3) Threshold (maximum): The upper limit of the variations between NG object is used as the judgment
condition.
Note
Measurement
value
Press [OK Teach] to register.
Press [NG Teach] to register.
Number of
registered
samples
3) 2) 1)