Menu Tables
444
FQ2-S/CH User’s Manual
Inspection
Settings
Teach
for OCR*
4
Meas. Parameter
Rotation
compensa-
tion
Turned ON when characters on the
workpiece are rotated because the
workpiece itself is rotated. Correction
is possible in a rotation range of ±15°.
ON
OFF (Default) Scene p. 156
Slant com-
pensation
Used when the characters are at a
slant. Correction is possible in a rota-
tion range of ±15°.
•ON
• OFF (Default)
Scene
p. 156
Hyphen
height upp.
th.
Sets the upper limit of the height of the
region to treat as a hyphen or other
symbol.
0 to 100 (Default: 30)
Scene
Hyphen
height low.
th.
Sets the lower limit of the height of the
region to treat as a hyphen or other
symbol.
0 to 100 (Default: 70) Scene
Slender
char. th.
Sets the ratio of the height to the width
of the detection rectangle to judge as
thin characters (I, J, 1, :, and /).
1 to 10 (Default: 3) Scene
Max Width
Setting
Set the Max Width Setting. ON
OFF (Default)
Scene
Max
Width
specify the max width for attempted
character string.
0 to 9,999
(Default: 0)
Scene
Max
Height
Specify the max height of the charac-
ter to be read.
0 to 9,999
(Default: 0)
Scene
Min
Height
Specify the min height of the character
to be read.
0 to 100
(Default: 50)
Scene
Reading
Length
If character strings with a variable
number of characters are to be read,
specify variable.
Variable (Default)
Fixed
Scene
Continuous test Same as [Continuous test] on the [Test] Tab Page. --- p. 340
for Bar code*
3
Insp. region
Moves the measurement region or
adjusts the size of the measurement
region.
--- Scene ---
Camera setup Same as Camera adjustments on the Image Tab Page. Scene p. 76
Meas. Parameter
Code type Sets the type of code to read.
JAN/EAN/UPC (Default)
Code39
Codebar
ITF
Code93
Code128 / GS 1-128
GS1 DataBar
Pharmacode
Scene p. 186
Code color Sets the color of the code to be read. Black (Default)
White
Scene p. 186
Composite
codes on/
off
Sets whether or not composite codes
are supported.
(Only valid for Code128/GS1-128,
GS1 Databar)
Yes
No (Default) Scene
Check digit
on/off
(Except for
Pharmac-
ode)
Sets whether there is a check digit. Yes (Default)
No
Scene
Direction
(For Phar-
macode
only)
Sets the direction in which to read. Horizontal mode (Default)
Vertical mode Scene
Reverse
on/off (For
Pharmac-
ode only)
Sets whether to use Reverse Mode. Yes
No (Default) Scene
Menu command Description Setting range Data