External Reference Parameters
FQ2-S/CH User’s Manual
487
Appendices
9
156
Mea-
sure-
ment
condition
Model mode
Set / Get
0: Stable
1: High-speed
0 --- ---
160
Judge-
ment
condi-
tions
Judgement upper
limit for search coor-
dinate X
Set / Get −99,999.9999 to 99,999.9999
99,999.999
9
---
Judgement
condition
161
Judgement lower
limit for search coor-
dinate X
Set / Get −99,999.9999 to 99,999.9999
−
99,999.999
9
---
Judgement
condition
162
Judgement upper
limit for search coor-
dinate Y
Set / Get −99,999.9999 to 99,999.9999
99,999.999
9
---
Judgement
condition
163
Judgement lower
limit for search coor-
dinate Y
Set / Get −99,999.9999 to 99,999.9999
−
99,999.999
9
---
Judgement
condition
164
Judgement upper
limit for search angle Set / Get −180 to 180 180 ---
Judgement
condition
165
Judgement lower
limit for search angle Set / Get −180 to 180 −180 ---
Judgement
condition
166
Judgement upper
limit for correlation Set / Get 0 to 100 100 ---
Judgement
condition
167
Judge-
ment
condi-
tions
Judgement lower
limit for correlation Set / Get 0 to 100 60 ---
Judgement
condition
168
Position compensa-
tion X upper limit Set / Get −99,999.9999 to 99,999.9999
99,999.999
9
---
Judgement
condition
169
Position compensa-
tion X lower limit Set / Get −99,999.9999 to 99,999.9999
−
99,999.999
9
---
Judgement
condition
170
Position compensa-
tion Y upper limit Set / Get −99,999.9999 to 99,999.9999
99,999.999
9
---
Judgement
condition
171
Position compensa-
tion Y lower limit Set / Get −99,999.9999 to 99,999.9999
−
99,999.999
9
---
Judgement
condition
172
Theta position com-
pensation upper limit Set / Get −180 to 180
180
---
Judgement
condition
173
Theta position com-
pensation lower limit Set / Get −180 to 180 −180 ---
Judgement
condition
310
Logging
condi-
tions
Data logging switch
for entire unit
Set / Get 0: Data logging OFF
1: Data logging ON
0 --- ---
311 Data logging switch
for judgement
Set / Get 0: Data logging OFF
1: Data logging ON
0 --- ---
312 Data logging switch
for scroll X
Set / Get 0: Data logging OFF
1: Data logging ON
0 --- ---
313 Data logging switch
for scroll Y
Set / Get 0: Data logging OFF
1: Data logging ON
0 --- ---
314 Data logging switch
for scroll θ
Set / Get 0: Data logging OFF
1: Data logging ON
0 --- ---
External
reference
number
Category Data name
Set / Get
Data range Default Expression
text string
Logged data/
Judgement