Possible Remedies
1 Use Single Secret Handshake to enter screen calibration. See Single
Secret Handshake Procedure below. Press each ‘X’ in sequence to
recalibrate the screen. Refer to procedure, System Tests (see "P80
System Tests" on page 63) . Ensure the person recalibrating is
standing on the machine and is not holding on to the console or any
other part of the machine while doing so.
Single Secret Handshake Procedure
Procedure
2 The Welcome screen will be the first screen you see when you
approach the P80 console. Press the Pause key and continue holding
it down while you double press (prior to 1.1 version software
release) or single press (1.1 version or after software release) in
sequential order an X configuration on the Volume and Channel key
pad (Channel Up, Volume Down, Volume Up, Channel Down).
Release the Pause key when done pressing the arrows.
Note: The keypad X configuration sequence should be not faster than 1
second between each key stroke. Any speed faster than 1 second may result
in an unsuccessful access to the sign-in screen.