Page 40
Upload Procedure
1 The P30 must be powered down before the upload procedure can be
initiated. Ensure that the P30 has not been used for a sufficient
time to allow the lower PCA to completely discharge. The light
emitting diode on the lower PCA will go out when the power supply is
discharged.
2 If the CSAFE port is in use, temporarily disconnect the RJ-45 cable
from the CSAFE port. If the CSAFE port is not in use, temporarily
remove the plastic plug from the CSAFE port.
3 Connect the PDA or computer interface cable to the CSAFE port.
4 Select the software file to be uploaded on the palm device or
computer.
5 Start pedaling the P30 or power up using the external power supply.
When the P30 powers up the upload will commence. You must continue
to pedal until the upload is complete, approximately 2 minutes.
6 Stop pedaling or disconnect the external power supply when the
upload is complete, and allow the lower PCA to completely discharge.
The light emitting diode on the lower PCA will go out when the power
supply is discharged.
7 Start pedaling the P30, after it has been allowed to power down, the
P30 will now be operating on the newly uploaded software.
8 Thoroughly, check the P30’s function per Checking the AMT Operation (on
page 125).