© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
P80 System Test Table
Auto Stop Test
TRM Only
1 Touch
, then Touch
.
2 The Auto stop test will start the belt
at 1 mph; count will be reset to 0, and
then count up with each step.
3 Touch STOP to end the test. Touch 
BACK to exit to Systems Test.
Belt Speed Test
TRM Only
1 Touch
, then Touch
.
2 The belt will start a 0.5 mph, using the
machine control paddle to increase by
0.1 mph increments. The console will
display motor current as the belt speed
increases or decreases.
3 Touch STOP to end the test. Touch 
BACK to exit to Systems Test.
Incline Test
TRM Only
1 Touch
, and then Touch
START.
2 Use the machine control paddle to change
the lift. The console will display the
analog to digital (A/D) incline position
number and the incline position in
percent of incline.
3 Touch STOP to end the test. Touch 
BACK to exit to Systems Test.
AMT Stride
Position Test
AMT Only
1 Touch
and then
Touch START.
2 The High, Low and Dynamic positions will
be displayed. The low position display
shows the lowest position reading
achieved during the test. The high
position display shows the highest
position reading achieved during the
test. The dynamic position display
changes with current stride position.
Stride on the AMT to the maximum
horizontal movement in both directions.
At maximum stride length the low stride
display should read 0 and the high
stride display should read 40.