© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Figure 56: Step Up Pulley
8 Tighten the input mounting bolts.
9 Select the QUICKSTART program and adjust the resistance  key until
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.
10 The Drive belt tension should read approximately 135 ± 5 lbs.
11 Place a belt gauge on the generator belt as shown in below.