EasyManua.ls Logo

Renesas RL78 Series - Page 614

Renesas RL78 Series
1879 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RL78/F13, F14 CHAPTER 8 TIMER RD
R01UH0368EJ0210 Rev.2.10 582
Dec 10, 2015
Figure 8-13. Format of Timer RD Output Control Register (TRDOCR) [PWM3 Mode]
Address: F0269H After Reset: 00H
Note 1
Symbol 7 6 5 4 3 2 1 0
TRDOCR TOD1
TOC1 TOB1 TOA1 TOD0
TOC0 TOB0 TOA0
TOD1 TRDIOD1 initial output level select R/W
Disabled in PWM3 mode. R/W
TOC1 TRDIOC1 initial output level select R/W
Disabled in PWM3 mode. R/W
TOB1 TRDIOB1 initial output level select R/W
Disabled in PWM3 mode. R/W
TOA1 TRDIOA1 initial output level select R/W
Disabled in PWM3 mode. R/W
TOD0 TRDIOD0 initial output level select R/W
Disabled in PWM3 mode. R/W
TOC0 TRDIOC0 initial output level select R/W
Disabled in PWM3 mode. R/W
TOB0
TRDIOB0 initial output level select
Note 2
R/W
0 Low initial output, high active level, high output at TRDGRB1 compare match, and low
output at TRDGRB0 compare match
R/W
1 High initial output, low active level, low output at TRDGRB1 compare match, and high
output at TRDGRB0 compare match
TOA0 TRDIOA0 initial output level select
R/W
0 Low initial output, high active level, high output at TRDGRA1 compare match, and low
output at TRDGRA0 compare match
R/W
1 High initial output, low active level, low output at TRDGRA1 compare match, and high
output at TRDGRA0 compare match
Notes 1. The value after reset is undefined when FRQSEL4 = 1 in the user option byte (000C2H/020C2H) and
TRD0EN = 0 in the PER1 register. If it is necessary to read the initial value, set f
CLK to fIH and TRD0EN =
1 before reading.
2. If the pin function is set for waveform output, the initial output level is output when the TRDOCR register
is set.

Table of Contents

Other manuals for Renesas RL78 Series

Related product manuals