45 and larger
ID Pattern detection
45 ID Pattern extract error Cannot detect ID Pattern
50 Vmin_Bk/K2 error(Max) K:Vmin_Bk / CMY:K2>Max
51 Vmin_Bk/K2 error(Min) K:Vmin_Bk / CMY:K2<Min
52 K5 error (Max) K5>Max
53 K5 error (Min) K5<Min
54
K5 calculated approximate
point error
K5 calculated approximate
point <Min
55
Development gamma error
(Max)
Development gamma >Max
56
Development gamma error
(Min)
Development gamma <Min
57
Start developing voltage: Vk
error(Max)
Start developing voltage:
Vk>Max
58
Start developing voltage: Vk
error(Min)
Start developing voltage:
Vk<Min
59 Not enough valid data
Adhesion amount data for
development gamma
calculation point is under 2
60 and larger
Potential adjustment
61 LD won’t light P patter is not written.
62 Residual potential: Vr error Vr>Max
63
Electrified potential: Vd adjust
error
Vd cannot be adjusted in target
range.
64
Exposure potential: Vpl adjust
error
Vpl cannot be adjusted in target
range
90 and larger
Result(End)
90 Potential not adjusted
Potential control method is set
as [0:FIX]
99 Stopped
Stopped by door open, power
off, error.
(Set when execute.)
7. Detailed Descriptions