1-950-003 Dev Cooling Fan *ENG [0 to 120 / 0 / 1min/step]
1-950-005 Ozone Fan *ENG
1-950-006 Fusing Fan *ENG
1-950-007 Paper Exit Cooling Fan *ENG
1-950-011 PSU Cooling Fan *ENG
1-950-051 Dev Suction Fan: Right *ENG
1951 [Fan Start Time Set]
1-951-003 Dev Cooling Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-005 Ozone Fan *ENG [0 to 900 / 0 / 1sec/step]
1-951-006 Fusing Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-007 Paper Exit Cooling Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-011 PSU Cooling Fan *ENG [0 to 900 / 120 / 1sec/step]
1-951-051 Dev Suction Fan: Right *ENG [0 to 900 / 0 / 1sec/step]
1952 [Fan Control Off Mode Time Set]
1-952-001 - *ENG [0 to 60 / 10 / 1min/step]
1953 [Extra Fan Control]
1-953-001 Extra Fan Cooling State
*ENG [0 or 1 / 0 / 1/step]
0: Disable
1: Enable
1-953-002 Execution Temp. Threshold
*ENG [0 to 100 / * / 0.1deg/step]
*MP C3004/C3504: 41
*MP C4504/C5504/C6004: 39
1-953-003 Cancellation Temp. Threshold *ENG [0 to 100 / 2 / 0.1deg/step]
3. Engine SP Mode Tables
218