1-953-004
Extra Fan Operation
ON/OFF Setting
*ENG [0 or 1 / 1 / 1/step]
0: disable
1: enable
1955 [Fan Control]
1-955-004
Dev Cooling Fan Op Sw
Temp
*ENG
[0 to 100 / 36 / 0.1deg/step]
1-955-006
Paper Exit Cooling Fan Op
Sw Temp
*ENG
[0 to 100 / 12 / 0.1deg/step]
1-955-007 Fusing Fan Op Sw Temp *ENG [0 to 100 / 0 / 0.1deg/step]
1-955-009
Ozone Fan Low Speed Op
Sw Temp
*ENG
[0 to 100 / 35 / 0.1deg/step]
1-955-010
Ozone Fan Middle Speed
Op Sw Temp
*ENG
[0 to 100 / 37 / 0.1deg/step]
1-955-011
Ozone Fan High Speed Op
Sw Temp
*ENG
[0 to 100 / 40 / 0.1deg/step]
1-955-012
Ozone Fan Low Noise Op
DUTY
*ENG
[0 to 100 / 20 / 1%/step]
1-955-013
Ozone Fan Low Speed Op
DUTY
*ENG
[0 to 100 / 30 / 1%/step]
1-955-014
Ozone Fan Middle Speed
Op DUTY
*ENG
[0 to 100 / 40 / 1%/step]
1-955-015
Ozone Fan High Speed Op
DUTY
*ENG
[0 to 100 / 40 / 1%/step]
1-955-016
Paper Exit Cooling Fan Op
Start Time A
*ENG
[0 to 900 / 300 / 1sec/step]
1-955-017
PSU Cooling Fan Op Start
Time A
*ENG [0 to 900 / * / 1sec/step]
*MP C3004/C3504: 300
*MP C4504/C5504/C6004:
*NA: 120, EU: 40, Asia: 40, CN: 40,
TW: 120 , KR: 40
1-955-018 Fan Op Sw Temp Thers *ENG [0 to 100 / 2 / 0.1deg/step]
Engine SP Tables-1