2009 [Charge AC Current: MM]
2-009-001 Environmental Target: Bk *ENG [0 to 3 / * / 0.01mA/step]
*MP C3004: 0.81
*MP C3504: 0.81
*MP C4504: 1.02
*MP C5504: 1.42
*MP C6004: 1.42
2-009-002 Environmental Target: C *ENG
2-009-003 Environmental Target: M *ENG
2-009-004
Environmental Target: Y
*ENG
2010 [Charge AC Current: MH]
2-010-001 Environmental Target: Bk *ENG [0 to 3 / * / 0.01mA/step]
*MP C3004: 0.83
*MP C3504: 0.83
*MP C4504: 1.05
*MP C5504: 1.45
*MP C6004: 1.45
2-010-002 Environmental Target: C *ENG
2-010-003 Environmental Target: M *ENG
2-010-004
Environmental Target: Y
*ENG
2011 [Charge AC Current: HH]
2-011-001 Environmental Target: Bk *ENG [[0 to 3 / * / 0.01mA/step]
*MP C3004: 0.86
*MP C3504: 0.86
*MP C4504: 1.08
*MP C5504: 1.48
*MP C6004: 1.48
2-011-002 Environmental Target: C *ENG
2-011-003 Environmental Target: M *ENG
2-011-004
Environmental Target: Y
*ENG
2012 [Charge Output Control]
2-012-001
AC Voltage
*ENG [0 or 1 / 0 / 1/step]
0: Set to environment correction value
used when FB .
1: Electrify AC voltage of SP: Set to fixed
setting value.
2013 [Environmental Correction: PCU]