2-013-001
Current Environmental FC :
Display
*ENG
[0 to 0 / 0 / 1/step]
2-013-002 Forced Setting *ENG [0 to 5 / 0 / 1/step]
2-013-003
Absolute Humidity: Threshold
1
*ENG
[0 to 100 / 3 / 0.01g/m
3
/step]
2-013-004
Absolute Humidity: Threshold
2
*ENG
[0 to 100 / 8 / 0.01g/m
3
/step]
2-013-005
Absolute Humidity: Threshold
3
*ENG
[0 to 100 / 15 / 0.01g/m
3
/step]
2-013-006
Absolute Humidity: Threshold
4
*ENG
[0 to 100 / 22 / 0.01g/m
3
/step]
2-013-007 Temp FC: Display *ENG [0 to 100 / 0 / 1deg/step]
2-013-008
Relative Humidity FC :
Display
*ENG
[0 to 100 / 0 / 1%RH/step]
2-013-009
Absolute Humidity FC :
Display
*ENG
[0 to 100 / 0 / 0.01g/m
3
/step]
2-013-010 Environmental Bk: Display *ENG [0 to 0 / 0 / 1/step]
2-013-011 Temp Bk.: Display *ENG [0 to 100 / 0 / 1deg/step]
2-013-012 Relative Humidity Bk : Display *ENG [0 to 100 / 0 / 1%RH/step]
2-013-013
Absolute Humidity Bk :
Display
*ENG
[0 to 100 / 0 / 0.01g/m
3
/step]
2014 [Charge AC Control: Setting]
2-014-001 Exec Interval: Power ON *ENG [0 to 2000 / 500 / 1page/step]
2-014-002 Exec Interval: Print *ENG [0 to 2000 / 0 / 1page/step]
2-014-003 Page Interval *ENG [0 to 500 / 10 / 1page/step]
2-014-004 Temperature *ENG [0 to 99 / 35 / 1deg/step]
2-014-005 Relative Humidity *ENG [0 to 99 / 50 / 1%RH/step]
2-014-006 Absolute Humidity *ENG [0 to 99 / 12 / 1g/m3/step]