3-521-003 Day *ENG [1 to 31 / 1 / 1day/step]
3-521-004 Hour *ENG [0 to 23 / 0 / 1hour/step]
3-521-005 Minute *ENG [0 to 59 / 0 / 1minute/step]
3-521-011 Year:Col *ENG [0 to 99 / 0 / 1year/step]
3-521-012 Month:Col *ENG [1 to 12 / 1 / 1month/step]
3-521-013 Day:Col *ENG [1 to 31 / 1 / 1day/step]
3-521-014 Hour:Col *ENG [0 to 23 / 0 / 1hour/step]
3-521-015 Minute:Col *ENG [0 to 59 / 0 / 1minute/step]
3522 [Drum Stop Environ :Disp]
3-522-001 Temperature *ENG [-1280 to 1270 / 0 / 0.1deg/step]
3-522-002 Rel Humidity *ENG [0 to 1000 / 0 / 0.1%RH/step]
3-522-003 Abs Humidity *ENG [0 to 1000 / 0 / 0.1g/m
3
/step]
3-522-011 Temperature:Col *ENG [-1280 to 1270 / 0 / 0.1deg/step]
3-522-012 Rel Humidity:Col *ENG [0 to 1000 / 0 / 0.1%RH/step]
3-522-013 Abs Humidity:Col *ENG [0 to 1000 / 0 / 0.1g/m
3
/step]
3529 [ProCon Interval Control :Set]
3-529-001 Gamma Corr
*ENG [0 or 1 / 1 / 1/step]
0: OFF
1: ON
3-529-002 Environ Corr
*ENG [0 or 1 / 1 / 1/step]
0: OFF
1: ON
3-529-003 AbsHum Threshhold *ENG [0 to 99 / 4.3 / 0.1g/m
3
/step]
3-529-004 Max Cnt Threshhold *ENG [0 to 99 / 2 / 1count/step]
3-529-005 Exe Cnt ENG [0 to 255 / 0 / 1count/step]