3-529-006 Page Cnt:BW *ENG [0 to 5000 / 0 / 1sheet/step]
3-529-007 Page Cnt:FC *ENG [0 to 5000 / 0 / 1sheet/step]
3530 [PowerON ProCon :Set]
3-530-001 Non-use Time Setting *ENG [0 to 1440 / 360 / 1minute/step]
3-530-002 Temperature Range *ENG [0 to 99 / 10 / 1deg/step]
3-530-003 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
3-530-004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m
3
/step]
3-530-005 Interval:BW *ENG [0 to 5000 / 250 / 1sheet/step]
3-530-006 Interval:FC *ENG [0 to 5000 / 100 / 1sheet/step]
3-530-007 Page Cnt:BW *ENG [0 to 5000 / 0 / 1sheet/step]
3-530-008 Page Cnt:FC *ENG [0 to 5000 / 0 / 1sheet/step]
3531 [Non-useTime Procon :Set]
3-531-001 Non-use Time Setting *ENG [0 to 1440 / 360 / 1minute/step]
3-531-002 Temperature Range *ENG [0 to 99 / 10 / 1deg/step]
3-531-003 Relative Humidity Range *ENG [0 to 99 / 50 / 1%RH/step]
3-531-004 Absolute Humidity Range *ENG [0 to 99 / 6 / 1g/m
3
/step]
3-531-005 Maximum Execution Number *ENG [0 to 99 / 10 / 1count/step]
3533 [Interrupt ProCon :Set]
3-533-001 Interval:Set:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-533-002 Interval:Disp:BW *ENG [0 to 5000 / 500 / 1sheet/step]
3-533-003 Corr(Short):BW *ENG [0 to 1 / 1 / 0.01/step]
3-533-004 Corr(Mid):BW *ENG [0 to 1 / 1 / 0.01/step]
3-533-011 Interval:Set:FC *ENG [0 to 5000 / 200 / 1sheet/step]
3-533-012 Interval:Disp:FC *ENG [0 to 5000 / 200 / 1sheet/step]