EasyManua.ls Logo

Ricoh MP C3004 - Page 969

Ricoh MP C3004
2154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC637-02 D Tracking Information Notification Error (Management server error)
Tracking information was lost.
Communication with tracking management server failed.
Network error
tracking management server error
Tracking SDK application error
Turn the main power off/on.
SC No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC641-00 D Communication error between BCU and Controller board.
Controller board does not respond after BCU tries to communicate three
times.
Controller board software error
Connect error between BCU and Controller board
Engine board software error
Check connections between Controller board and BCU.
Turn the main switch off and on.
SC No. Type Error Name/Error Condition/Major Cause/Solution
SC650-01 C Remote Service Modem Communication Error (Dialup authentication
failure)
An error related to communication (dialup connection, modem
board etc.) using the RC Gate Type M was detected or an error that
prevents RC Gate operation was detected at power on.
Displayed only when an error is detected while RC Gate is
operating.
SC is not issued if an error occurs during RC Gate installation
(because it can be referenced using SP).
Dialup authentication failure
SC620-Service Call 620-689
961

Table of Contents

Related product manuals