SC No. Type Error Name/Error Condition/Major Cause/Solution
SC722 Finisher SR3210 (D3B8) Error
SC722-03 B Protection Device Intercept Error 1
Fuse blowout is detected
SC722-06 C See the descriptions next table below.
SC722-10 B Transport Motor 1 Error
Motor driver detects an error state (DC motor control error) (1st time is
jam notification, 2nd time is SC notification).
SC722-11 B Transport Motor 2 Error
Motor driver detects an error state (DC motor control error) (1st time is
jam notification, 2nd time is SC notification).
SC722-17 B Paper Eject Motor 2 Error
Motor driver detects an error state (DC motor control error) (1st time is
jam notification, 2nd time is SC notification).
SC722-24 B Paper Exit Guide Plate Open/Close motor Error
During movement to home, the home position could not be detected
within a predetermined pulse (1st time is jam notification, 2nd time is
SC notification).
During movement from home, the home position was detected for
longer than a predetermined pulse (1st time is jam notification, 2nd
time is SC notification).
SC722-25 B Punch Drive Motor Error
During movement to home, the home position could not be detected
within a predetermined time (1st time is jam notification, 2nd time is
SC notification).
During movement from home, the home position was detected even
after a predetermined time elapsed (1st time is jam notification, 2nd
time is SC notification).
Output from the encoder could not be counted for a predetermined
number of times within a predetermined time (1st time is jam
notification, 2nd time is SC notification).