Remote control commandsMXO 4 Series
749User Manual 1335.5337.02 ─ 07
SBUS<sb>:UART:POLarity <Polarity>
Defines the logic levels of the bus. The idle state corresponds to a logic 1. The start bit
corresponds to a logic 0. "Idle high" (high=1) is used, for example, for control signals,
while "Idle low" (low=1) is defined for data lines (RS-232).
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Polarity> IDLLow | IDLHigh
*RST: IDLHigh
Usage: Asynchronous command
Manual operation: See "Polarity" on page 357
SBUS<sb>:UART:RX:HYSTeresis <Rx hysteresis>
Sets the hysteresis for the Tx line.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<Rx hysteresis>
Usage: Asynchronous command
Manual operation: See "Threshold" on page 358
SBUS<sb>:UART:RX:SOURce RXSource
Selects the input channel for the receiver signal.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
RXSource C1 | C2 | C3 | C4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9
| D10 | D11 | D12 | D13 | D14 | D15 | M1 | M2 | M3 | M4 | M5 |
R1 | R2 | R3 | R4
Usage: Asynchronous command
Manual operation: See "Source: Tx, Rx" on page 356
SBUS<sb>:UART:RX:THReshold <Rx threshold>
Sets a user-defined threshold value for the Rx line.
Suffix:
<sb>
.
1...4, index of the serial bus