Remote control commandsMXO 4 Series
754User Manual 1335.5337.02 ─ 07
Parameters:
<Source> TX | RX
*RST: TX
Usage: Asynchronous command
Manual operation: See "Trigger source" on page 362
TRIGger:UART:TYPE <Type>
Selects the trigger condition.
Parameters:
<Type> STBT | PCKS | DATA | PRER | BRKC | STPerror
STBT: Start bit
PCKS: Packet start
DATA: Serial pattern
BRKC: Break condition
STPerror: Stop error
*RST: STBT
Usage: Asynchronous command
Manual operation: See "Type" on page 362
17.16.4.3 Filter
SBUS<sb>:UART:FILTer:CHKall...................................................................................... 755
SBUS<sb>:UART:FILTer:CLR..........................................................................................755
SBUS<sb>:UART:FILTer:INVert....................................................................................... 755
SBUS<sb>:UART:FILTer:RST..........................................................................................755
SBUS<sb>:UART:FILTer:IMIN......................................................................................... 755
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:IMIN........................................................... 755
SBUS<sb>:UART:FILTer:IMAX........................................................................................ 756
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:IMAX.......................................................... 756
SBUS<sb>:UART:FILTer:IOPerator.................................................................................. 756
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:IOPerator.................................................... 756
SBUS<sb>:UART:FILTer:ERENable................................................................................. 757
SBUS<sb>:UART:FILTer:ERRor<n>:ENABle.....................................................................757
SBUS<sb>:UART:FILTer:DOPerator.................................................................................757
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:DOPerator...................................................757
SBUS<sb>:UART:FILTer:DMIN........................................................................................757
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:DMIN..........................................................757
SBUS<sb>:UART:FILTer:DMAX.......................................................................................758
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:DMAX.........................................................758
SBUS<sb>:UART:FILTer:BIT........................................................................................... 758
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:BIT............................................................. 758
SBUS<sb>:UART:FILTer:FRENable................................................................................. 758
SBUS<sb>:UART:FILTer:FRAMe<fr>:ENABle................................................................... 758
SBUS<sb>:UART:FILTer:FIENable...................................................................................759
SBUS<sb>:UART:FILTer:FRAMe<fr>:FLD<fl>:ENABle.......................................................759
Protocols