Remote control commandsMXO 4 Series
760User Manual 1335.5337.02 ─ 07
Usage: Query only
Asynchronous command
SBUS<sb>:UART:WORD<w>:COUNt?
Returns the number of words in the acquisition.
Suffix:
<sb>
.
1...4, index of the serial bus
<w> *
The suffix is irrelevant.
Return values:
<Count> Number of words
Usage: Query only
Asynchronous command
SBUS<sb>:UART:WORD<w>:RXValue?
Returns the value of the specified word on the Rx line.
Suffix:
<sb>
.
1...4, index of the serial bus
<w> index of the word
Return values:
<RxValue> Range: 0 to 511
Increment: 1
*RST: 0
Usage: Query only
Asynchronous command
SBUS<sb>:UART:WORD<w>:SOURce?
Returns the line on which the specified word was transferred.
Suffix:
<sb>
.
1...4, index of the serial bus
<w> index of the word
Return values:
<WordSource> TX | RX
*RST: TX
Usage: Query only
Asynchronous command