EasyManua.ls Logo

Rohde & Schwarz MXO 4 Series - Page 777

Rohde & Schwarz MXO 4 Series
925 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commandsMXO 4 Series
777User Manual 1335.5337.02 ─ 07
Parameters:
<VcidPattern> List of comma separated values
Usage: Asynchronous command
Manual operation: See "VCID" on page 384
17.16.5.3 Filter
SBUS<sb>:CAN:FILTer:CHKall........................................................................................777
SBUS<sb>:CAN:FILTer:CLR........................................................................................... 777
SBUS<sb>:CAN:FILTer:INVert.........................................................................................778
SBUS<sb>:CAN:FILTer:RST........................................................................................... 778
SBUS<sb>:CAN:FILTer:ENABle...................................................................................... 778
SBUS<sb>:CAN:FILTer:BIT.............................................................................................778
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:BIT...............................................................778
SBUS<sb>:CAN:FILTer:DMAX........................................................................................ 779
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:DMAX.......................................................... 779
SBUS<sb>:CAN:FILTer:DMIN......................................................................................... 779
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:DMIN........................................................... 779
SBUS<sb>:CAN:FILTer:DOPerator.................................................................................. 779
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:DOPerator.................................................... 779
SBUS<sb>:CAN:FILTer:ERENable...................................................................................780
SBUS<sb>:CAN:FILTer:ERRor<n>:ENABle...................................................................... 780
SBUS<sb>:CAN:FILTer:FIENable.................................................................................... 780
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:ENABle........................................................ 780
SBUS<sb>:CAN:FILTer:FRENable...................................................................................780
SBUS<sb>:CAN:FILTer:FRAMe<fr>:ENABle.....................................................................780
SBUS<sb>:CAN:FILTer:IMAX..........................................................................................781
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:IMAX............................................................781
SBUS<sb>:CAN:FILTer:IMIN...........................................................................................781
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:IMIN.............................................................781
SBUS<sb>:CAN:FILTer:IOPerator....................................................................................782
SBUS<sb>:CAN:FILTer:FRAMe<fr>:FLD<fl>:IOPerator......................................................782
SBUS<sb>:CAN:FILTer:CHKall
Enables the filter for all available frames and error types.
Suffix:
<sb>
.
1...4, index of the serial bus
Usage: Setting only
Asynchronous command
Manual operation: See "Check all, Clear, Invert, Reset" on page 375
SBUS<sb>:CAN:FILTer:CLR
Disables the filter for all available frames and error types.