EasyManua.ls Logo

Rohde & Schwarz MXO 4 Series - Page 799

Rohde & Schwarz MXO 4 Series
925 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commandsMXO 4 Series
799User Manual 1335.5337.02 ─ 07
TRIGger:LIN:CHKSerror <ChecksumError>
Triggers on checksum errors.
Available, if TRIGger:LIN:TYPE is set to ERRC.
Parameters:
<ChecksumError> ON | OFF
*RST: ON
Usage: Asynchronous command
Manual operation: See "Error conditions" on page 398
TRIGger:LIN:DCONdition <DataOperator>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<DataOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, not equal, less than, less or equal than, greater than,
greater or equal than. These conditions require one data pattern
to be set with TRIGger:LIN:DMIN.
*RST: EQUal
Usage: Asynchronous command
Manual operation: See "Data setup: Condition, Pattern, Position" on page 397
TRIGger:LIN:DMIN <DataPattern>
Specifies a data pattern, or sets the start value of a data pattern range.
Parameters:
<DataPattern> List of comma separated values
Usage: Asynchronous command
Manual operation: See "Data setup: Condition, Pattern, Position" on page 397
TRIGger:LIN:DPOSition <DataPosition>
Sets the number of data events that are ignored, before trigger condition check of the
data starts.
Parameters:
<DataPosition> Range: 1 to 4096
Increment: 1
*RST: 1
Usage: Asynchronous command
Manual operation: See "Data setup: Condition, Pattern, Position" on page 397
Protocols