Instrument Function
R&S
®
SMU200A
434Operating Manual 1007.9845.32 ─ 15
"ON/OFF
Period"
A regular marker signal that is defined by an ON/OFF ratio is generated.
A period lasts one ON and OFF cycle.
The "ON Time" and "OFF Time" are each expressed as a number of
samples and are set in an input field which opens when ON/OFF ratio is
selected.
SCPI command:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:ONTime on page 684
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:OFFTime on page 684
SCPI command:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:MODE on page 683
Marker Delay
The delay of the signals on the MARKER outputs is set in the"Marker Delay" section.
Marker x Delay
Enters the delay between the marker signal at the marker outputs and the start of the
frame or slot.
The input is expressed as a number of symbols. If the setting "Fix marker delay to dynamic
range" is enabled, the setting range is restricted to the dynamic range. In this range the
delay of the marker signals can be set without restarting the marker and signal.
SCPI command:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay on page 682
Current Range without Recalculation
Displays the dynamic range within which the delay of the marker signals can be set with-
out restarting the marker and signal.
The delay can be defined by moving the setting mark.
SCPI command:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay:MINimum on page 683
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay:MAXimum on page 682
Fix marker delay to current range
Restricts the marker delay setting range to the dynamic range. In this range the delay
can be set without restarting the marker and signal.
SCPI command:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut:DELay:FIXed on page 682
Clock Settings
The Clock Settings is used to set the clock source and a delay if required.
Baseband Signal - Baseband Block