Commands listed in alphabetical order
Conditions
Requires optio
nSR-AUTO.
Group
Bus
Syntax
BUS:B<x>:CAN:FD:BITRate:CU STom <NR1>
BUS:B<x>:CAN:FD:BITRate:CU STom?
Related Commands
BUS:B<x>:CAN:BITRate
Arguments
<NR1> is the c ustom FD bit rate for the specified bus.
Examples
BUS:B1:CAN:FD:BITRATE:CUST OM 1000000 sets the bit rate to 1,000,000.
BUS:B1:CAN:FD:BITRATE:CUST OM? might return
:BUS:B1:CAN:FD:BITRATE:CUS TOM 4000000, indicating the bit rate is set
to 4,000,000.
BUS:B<x>:CAN:SAMPLEpoint
This command sets or queries the sample point for the specified CAN bus. The
b
us is specified by x.
Conditions
Requires option SR-AUTO.
Group
Bus
Syntax
BUS:B<x>:CAN:SAMPLEpoint <NR1>
BUS:B<x>:CAN:SAMPLEpoint?
Arguments
<NR1> is the sample point, in percent, for the specified CAN bus.
Examples
BUS:B1:CAN:SAMPLEpoint 40 sets the sample point to 40%.
BUS:B1:CAN:SAMPLEpoint? might return :BUS:B1:CAN:SAMPLEPOINT 50
indicating the sample point is at 50%.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-129