MEASUrement:
MEAS<x>:POLarity
This command sets or queries the polarity for the measurement when the
measurement type is burst width. Measurements are specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:POLari ty {NORMal|INVerted}
MEASUrement:MEAS<x>:POLari ty?
Arguments
NORMal species normal polarity.
INVerted species inverted polarity.
Examples
MEASUrement:MEAS1:POLarity INVERTED species inverted polarity.
MEASUrement:MEAS1:POLarity ? mig
ht return
:MEASUREMENT:MEAS1:POLARIT Y NORMAL indicating normal polarity.
MEASUrement:MEAS<x>:POPUlation:GLOBal
This command sets or queries the population settings global ag. The
measurement number is specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:POPUla tion:GLOBal {OFF|ON|0|1}
MEASUrement:MEAS<x>:POPUla tion:GLOBal?
Arguments
OFF species that population settings can be changed independently for each
individual measurement.
ON applies the global population settings to all the measurements' population
settings.
0 species that population settings can be changed independently for each
individual measurement.
1 applies the global population settings to all the measurements' population
settings.
Examples
MEASUrement:MEAS1:POPUlati on:GLOBal 1 applies the global population
settings to all the measurements' population settings.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-467

Table of Contents

Other manuals for Tektronix MSO54

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
Analog Channels4
Sample Rate6.25 GS/s
Vertical Resolution12-bit
Form FactorBenchtop
Probe InterfaceTekVPI
Operating Temperature0 °C to +50 °C
Bandwidth1 GHz
Record Length62.5 Mpoints
Display15.6 inch HD
Waveform Update Rate>500, 000 wfms/s
Trigger TypesEdge, Pulse, Runt, Logic, Serial
Serial Bus SupportI2C, SPI, RS-232/422/485/UART, CAN/CAN FD/LIN, USB 2.0, Ethernet
ConnectivityUSB, Ethernet
Input Impedance1 MΩ
Power Requirements100-240 VAC, 50/60 Hz
Maximum Input Voltage400 V (DC + peak AC)

Related product manuals