Commands listed in alphabetical order
Examples
TRIGGER:A:BUS
:B1:FLEXRAY:FRAMEID:QUALIFIE R LESSTHAN
sets the
frame ID qualifier to less than.
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:QUALIFIER? might return
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:QUALIFIER EQUAL indicating the
frame ID qualifier is set to equal.
TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEID:VALue
This command specifies the low value when triggering on the FlexRay bus frame
ID field. (Use TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEID:HIVALue to
set the high value.) The trigger condition needs to be set to IDentifier (using
TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition). The bus number is specified
by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:FL EXray:FRAMEID:VALue <QStr ing>
TRIGger:{A|B}:BUS:B<x>:FL EXray:FRAMEID:VALue?
Arguments
<QString> is a quoted string that is the FlexRay frame ID low value.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:VALUE "11001100101" sets the
frame ID value to 11001100101.
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:VALUE? might return
TRIGGER:A:BUS:B1:FLEXRAY: FRAMEID:VALUE "XXXXXXXXXXX" indicating
the frame ID value is don't care.
TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEType
This command specifies the frame type (normal, payload, null, sync or startup)
when triggering on the FlexRay bus signal. The t rigger condition needs to be
set to FRAMEType (using TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition).
The bus number is specified by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
2-802 MSO54, MSO56, MSO58, MSO58LP Programmer