Commands listed in alphabetical order
Group
Bus
Syntax
BUS:B<x>:USB:DATAPLUSTHRES Hold <NR3>
BUS:B<x>:USB:DATAPLUSTHRES Hold?
Arguments
<NR3> is the P lus threshold.
Examples
BUS:B1:USB:DATAPLUSTHRESHo ld 50.0e-3 sets the threshold to 50.0 mV.
BUS:B1:USB:DATAPLUSTHRESHo ld? might return
:BUS:B1:USB:DATAPLUSTHRESH OLD 0.0E+0 indicating the threshold is
set to 0.0 V.
BUS:B<x>:USB:LOWTHRESHold
This command sets or queries the USB data source threshold for the specified bus
when the signal type is differential. The bus is specified by x.
Conditions
Requires option SR-USB2.
G
roup
B
us
Syntax
BUS:B<x>:USB:LOWTHRESHold <NR3>
BUS:B<x>:USB:LOWTHRESHold?
Arguments
<NR3> is the L ow threshold.
Examples
BUS:B1:USB:LOWTHRESHold 50.0e-3 sets the threshold to 50.0 mV.
BUS:B1:USB:LOWTHRESHold? might return :BUS:B1:USB :LOWTHRESHOLD
0.0E+0
indicating the threshold is set to 0.0 V.
BUS:B<x>:USB:SIGNALTYpe
This command sets or queries the USB signal type for the specified bus. The
bus is specified by x.
Conditions
Requires option SR-USB2.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-179