Commands listed in alphabetical order
For Cycle Base m
easurement, the parameters is “LOW”.
For Cycle Max measurement, the parameters is “MAX”.
For Cycle Min measurement , the parameters is “MIN”.
Examples
POWer:POWer1:RESUlts:CURRe ntacq:STDDev? “TONLoss” might
return 9.91E+37, indicating the standard deviation value of Ton Energy for all
acquisitions.
POWer:POWer<x>:RESUlts:CURRentacq:F1MAG? (Query Only)
This command queries the rst harmonics magnitude value for the specied
power measurement badge. The power measurement badge is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:RESUlts:CUR Rentacq:F1MAG? "harmonics"
Examples
POWer:POWer1:RESUlts:CURRe ntacq:F1MAG? "harmonics" might return
1.4151834770090, indicating the value of the rst harmonics magnitude for the
power measurement badge 1.
POWer:POWer<x>:RESUlts:CURRentacq:F3MAG? (Query Only)
This command queries the third harmonics magnitude value for the specied
power measurement badge. The power measurement badge is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:RESUlts:CUR Rentacq:F3MAG? "harmonics"
Examples
POWer:POWer1:RESUlts:CURRe ntacq:f3MAG? "harmonics" might return
234.0187140104806E-6, indicating the value of third harmonics magnitude for
the power measurement badge 1.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-569

Table of Contents

Other manuals for Tektronix MSO54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
BrandTektronix
ModelMSO54
CategoryTest Equipment
LanguageEnglish

Related product manuals