Commands listed in alphabetical order
SEARCH:SEARCH
1:TRIGger:A:BUS:FLEXRAY:COND ition?
might return
:SEARCH:SEARCH1:TRIGGER:A: BUS:FLEXRAY:CONDITION SOF, indicating
the FlexRay trigger condition is start of frame.
SEARCH:SEAR
CH<x>:TRIGger:A:BUS:FLEXRAY:CYCLEcount:HIVALue
This command sets or queries the heigh value when searching on a FlexRay bus
cycle count fi eld. The search number is specified by <x>. The search condition
must be set
to CYCLEcount.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:FLEXRAY:CYCLEcount:HIVALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A :BUS:FLEXRAY:CYCLEcount:HIVALue?
Arguments
<QString> specifies the cycle count value.
Examples
SEARCH:SEARCH1:TRIGger:A:B US:FLEXRAY:CYCLEcount:HIVALue
"1010"
sets the cycle count value to XX1010.
SEARCH:SEARCH1:TRIGger:A:B US:FLEXRAY:CYCLEcount:HIVALue?
might return
:SEARCH:SEARCH1:TRIGGER:A: BUS:FLEXRAY:CYCLECOUNT:HIVALUE
"XXXXX
X"
, indicating the cycle count value is don’t care, and it will trigger on
any cycle count.
SEARCH:SEARCH<x>:TRIGger:A:BUS:FLEXRAY:CYCLEcount:QUALifier
This command sets or queries the qualifier to be used when searching on a
FlexRay bus search cycle count fi eld. The search number is specified by <x>. The
search condition must be set to CYCLEcount.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Search and Mark
MSO54, MSO56, MSO58, MSO58LP Programmer 2-663