MEASUrement:
REFLevels:ABSolute:HYSTeresis
This command sets or queries the value of the hysteresis of the reference level
when the measurement's ref level m ethod is set to absolute.
Group
Measurement
Syntax
MEASUrement:REFLevels:ABS olute:HYSTeresis <NR3>
MEASUrement:REFLevels:ABS olute:HYSTeresis?
Arguments
<NR3> is the value of the hysteresis of the reference level.
Examples
MEASUrement:REFLevels:ABS olute:HYSTeresis 20.0E-3 sets the
hysteresis to 20.0 mV.
MEASUrement:REFLevels:ABS olute:HYSTeresis? might return
:MEASUREMENT:REFLEVELS:AB SOLUTE:HYSTERESIS 30.0000 E-3
indicating the hysteresis is set to 30.0 mV.
MEASUrement:REFLevels:ABSolute:RISEHigh
This command sets or queries the value used as the high reference level of the
rising edge when the m easurement's ref level method is set to absolute.
Group
Measurement
Syntax
MEASUrement:REFLevels:ABS olute:RISEHigh <NR3>
MEASUrement:REFLevels:ABS olute:RISEHigh?
Arguments
<NR3> is the value used as the high reference level of the rising edge.
Examples
MEASUrement:REFLevels:ABS olute:RISEHigh 1.5 sets the high reference
to 1.5 V.
MEASUrement:REFLevels:ABS olute:RISEHigh? might return
:MEASUREMENT:REFLEVELS:AB SOLUTE:RISEHIGH 1.0000 indicating the
high reference is 1.0 V.
2-498 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents

Other manuals for Tektronix MSO54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
BrandTektronix
ModelMSO54
CategoryTest Equipment
LanguageEnglish

Related product manuals