Commands listed in alphabetical order
Arguments
<NR3> is the per
centage (where 100% is equal to HIGH) used to calculate the
high reference level.
Examples
MEASUremen
t:MEAS1:REFLevels1:PERCent:F ALLHigh 95.0
sets the high
reference level of the falling edge to 95%.
MEASUrem
ent:MEAS1:REFLevels1:PERCen t:FALLHigh?
might return
:MEASUREMENT:MEAS1:REFLEVE LS1:PERCENT:FALLHIGH 90.0 000
indicating the high reference level is set to 90%.
MEASUre
ment:MEAS<x>:REFLevels<x>:PERCent:FALLLow
This command sets or queries the percentage (where 100% is equal to TOP and
0% is equal to BASE) used to calculate the low reference level of the falling edge
when t
he measurement's ref level method is set to percent. The measurement
number is specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:REFLev els<x>:PERCent:FALLLow <N R3>
MEASUrement:MEAS<x>:REFLev els<x>:PERCent:FALLLow?
Arguments
<NR3> is the percentage (where 100% is equal to HIGH) used to calculate the
mid reference level.
Examples
MEASUrement:MEAS1:REFLevel s1:PERCent:FALLLow 5.0 sets the low
reference level of the falling edge is 5%.
MEASUrement:MEAS1:REFLevel s1:PERCent:FALLLow? might return
:MEASUREMENT:MEAS1:REFLEVE LS1:PERCENT:FALLLOW 10.00 00
indicating the low reference level of the falling e dge is 10%.
MEASUrement:MEAS<x>:REFLevels<x>:PERCent:FALLMid
This command sets or queries the percentage (where 100% is equal to TOP and
0% is equal to BASE) used to calculate the mid reference level of the falling edge
when the measurement's ref level method is set to percent. The measurement
number is specied by x.
Group
Measurement
MSO54, MSO56, MSO58, MSO58LP Programmer 2-475

Table of Contents

Other manuals for Tektronix MSO54

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
Analog Channels4
Sample Rate6.25 GS/s
Vertical Resolution12-bit
Form FactorBenchtop
Probe InterfaceTekVPI
Operating Temperature0 °C to +50 °C
Bandwidth1 GHz
Record Length62.5 Mpoints
Display15.6 inch HD
Waveform Update Rate>500, 000 wfms/s
Trigger TypesEdge, Pulse, Runt, Logic, Serial
Serial Bus SupportI2C, SPI, RS-232/422/485/UART, CAN/CAN FD/LIN, USB 2.0, Ethernet
ConnectivityUSB, Ethernet
Input Impedance1 MΩ
Power Requirements100-240 VAC, 50/60 Hz
Maximum Input Voltage400 V (DC + peak AC)

Related product manuals