SEARCH:SEARC
H<x>:TRIGger:A:BUS:USB:SPLIT:PORT:VALue
This co mmand sets or queries the binary port address used when searching on a
USB bus signal. The search number is specied by <x>. The search c ondition
must be set to
Special with a packet type SPLIT.
Conditions
Requires the SR-USB2 Serial Triggering and Analysis Application.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:USB:SPLIT:PORT:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A :BUS:USB:SPLIT:PORT:VALue?
Arguments
<QString> species the port address in the valid format. The valid characters are
Examples
SEARCH:SEARCH1:TRIGGER:A:B US:USB:SPLIT:PORT:VALUE " 1111" sets
the port address for USB bus trigger search 1 to "XXX1111" for binary format.
SEARCH:SEARCH1:TRIGGER:A:B US:USB:SPLIT:PORT:VALUE? might
return
SEARCH:SEARCH1:TRIGGER:A:BU S:USB:SPLIT:PORT:VALUE "X X",
indicating that the port address for USB hub trigger search 1 is set to "XX"
in hexadecimal format.
SEARCH:SEARCH<x>:TRIGger:A:BUS:USB:SPLIT:SC:VALue
This command sets or queries the Start/Complete value for the specied USB bus
trigger on split token eld search to determine where to place a mark. The search
number is specied by <x>.
Conditions
Requires the SR-USB2 Serial Triggering and Analysis Application.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger:A :BUS:USB:SPLIT:SC:VALue
{CSPLIT|NOCARE|SSPLIT}
SEARCH:SEARCH<x>:TRIGger:A :BUS:USB:SPLIT:SC:VALue?
Arguments
CSPLIT species Complete (CSPLIT)(1) Start/Complete value.
NOCARE species the Start
/Complete value as Don’t Care (X).
MSO54, MSO56, MSO58, MSO58LP Programmer 2-711

Table of Contents

Other manuals for Tektronix MSO54

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO54 and is the answer not in the manual?

Tektronix MSO54 Specifications

General IconGeneral
Analog Channels4
Sample Rate6.25 GS/s
Vertical Resolution12-bit
Form FactorBenchtop
Probe InterfaceTekVPI
Operating Temperature0 °C to +50 °C
Bandwidth1 GHz
Record Length62.5 Mpoints
Display15.6 inch HD
Waveform Update Rate>500, 000 wfms/s
Trigger TypesEdge, Pulse, Runt, Logic, Serial
Serial Bus SupportI2C, SPI, RS-232/422/485/UART, CAN/CAN FD/LIN, USB 2.0, Ethernet
ConnectivityUSB, Ethernet
Input Impedance1 MΩ
Power Requirements100-240 VAC, 50/60 Hz
Maximum Input Voltage400 V (DC + peak AC)