Commands listed in alphabetical order
Syntax
MEASUrement:M
EAS<x>:CLOCKRecovery:NOMINAL OFFset:
SELECTIONtype {AUTO|MANUAL}
MEASUrement:MEAS<x>:CLOCKR ecovery:NOMINALOFFset:
SELECTIONtyp
e?
Arguments
AUTO automatically calculates the offset.
MANUAL allows the u ser to set the offset.
Examples
MEASUrement:MEAS1:CLOCKRec overy:NOMINALOFFset:SELECTIONtype
AUTO
sets the offset selection type to auto.
MEASUrement:MEAS1:CLOCKRec overy:NOMINALOFFset:SELECTIONtype?
might return
:MEASUREMENT:MEAS1:CLOCKRE COVERY:NOMINALOFFSET:SELECTIONTYPE
MANUAL
indicating the selection type is manual.
MEASUrement:MEAS<x>:CLOCKRecovery:STAndard
This command sets or queries the communications standard when PLL clock
recovery is used for the measurement. The measurement number is specified by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:CLOCKR ecovery:STAndard {CUSTom|
ENET100|FW1394BS400B|FW139 4BS800B|FW1394BS1600B|FBD1|
FBD2|FBD3|FC133|FC266|FC53 1|FC1063|FC2125|FC4250|
FC8500|ENET1000|IBA2500|IB A_GEN2|OC1|OC3|OC12|OC48|
PCIE_GEN1|PCIE_GEN2|PCIE_G EN3|RIO125|RIO250|RIO3125|
SAS15_NOSSC|SAS3_NOSSC|SAS 6_NOSSC|SAS12_NOSSC|SAS15_SSC|
SAS3_SSC|SAS6_SSC|SAS12_SS C|SATA_GEN1|SATA_GEN2|
SATA_GEN3|USB3|XAUI|XAUI_G EN2}
Arguments
Arguments are the clock recovery standards.
Examples
MEASUrement:MEAS1:CLOCKRec overy:STAndard PCIE_GEN2 sets the
standard to
PCIE_GEN2.
MEASUrement:MEAS1:CLOCKRec overy:STAndard? might return
:MEASUREMENT:MEAS1:CLOCKRE COVERY:STANDARD PCIE_GEN1 indicating
the standard is
PCIE_GEN1.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-439