P a g e | 259
UCM6510 IP PBX User Manual
Version 1.0.20.31
Conference Settings
Figure 151 : Video Conference Basic settings
Table 77: Video Conference Basic Settings
Basic Settings
Video Conferencing
This option should be enabled in order to activate the Video Conference
feature.
Bind UDP Port
Configure the UDP port number for MCM. The standard UDP port for MCM
is 5062.
Packet Loss Retransmission
Configure to enable Packet Loss Retransmission.
FEC
If enabled, the Forward Error Correction (FEC) will be activated. The
default setting is "No".
Enable Talk Detection
If enabled, the AMI will send the corresponding event when a user starts
or stops talking.
DSP Talking Threshold
The amount of time (ms) that sound exceeds what the DSP has
established as the baseline for silence before a user is considered to be
talking. This value affects several operations and should not be changed
unless the impact on call quality is fully understood.
DSP Silence Threshold
The amount of time(ms) that sound falls within what the DSP has
established as the baseline for silence before a user is considered be

Table of Contents

Other manuals for Grandstream Networks UCM6510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks UCM6510 and is the answer not in the manual?

Grandstream Networks UCM6510 Specifications

General IconGeneral
BrandGrandstream Networks
ModelUCM6510
CategoryPBX
LanguageEnglish

Related product manuals