1148 HEIDENHAIN Technical Manual MANUALplus 620
Type of display: Set the time interval for recording the signals.
YT: Chronological depiction of the channels
YX: Graph of two channels
Circle: Circular interpolation test, see page 1158
Sampling time: Set the time interval for recording the signals.
CC clock: Time interval = 0.6 ms
IPO clock: Time interval = IPO clock
(from MP_System/CfgCycleTimes/ipoCycle)
PLC clock: Time interval = PLC clock
(results from MP_System/CfgCycleTimes/plcCount * Ipo clock)
3000 grid points (events) are stored. The time grid determines the duration of
recording.
Examples:
0.6 ms 3000 = 1.8 s
3 ms 3000 = 9 s
21 ms 3000 = 63 s
Channel 1 to channel 6
Specify the signals to be recorded:
Assign the channels of the analog signals to be recorded to the respective
axes.
Specify the operand type (B,W,D,I,O,T,C) and the address for the recording
of PLC operands.
Use the SAVED setting to "freeze" the signal last recorded for this channel.
This means that the recorded values remain available on the display. For
example, you can use them to record a reference curve for use in future
measurements.