EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - 3.6.4 Power supply of the CC 61 xx

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2012 3.6 Supply Voltages in the HSCI System 185
3.6.4 Power supply of the CC 61xx
The CC 61xx controller unit is supplied with a power of +5 V by the power sup-
ply units via supply bus X69 and connector X74, see page 186.
The control monitors the 5 V supply voltage. If it drops below 4.75 V, the error
message 5 V power supply too low appears. If it rises above 5.4 V, 5 V power
supply too high is indicated.
For information on the power supply units, refer to the "Inverter Systems
and Motors" Technical Manual.
Device Load capacity
UVR 1xxD, UE 2xxD 20.00 A via X74
10.00 A via X69
Device Current consumption of the 5 V supply
CC 6106/6 control loops 3.80 A
Consisting of:
1 drive-control motherboard: 2.00 A
2 drive-control expansion boards: 0.90 A
each
CC 6108/8 control loops 5.80 A
Consisting of:
2 drive-control motherboards: 2.00 A
2 drive-control expansion boards: 0.90 A
each
CC 6110/10 control loops 6.70 A
Consisting of:
2 drive-control motherboards: 2.00 A
3 drive-control expansion boards: 0.90 A
each
UxC drive control board 2.50 A
LS, LB 0.15 A
ERN, ROD, RON 0.20 A
Absolute rotary encoders 0.25 A (+0.085 A with line-drop compen-
sator)
a
a. For cable lengths > 10 m between the logic unit and the encoders
with EnDat interfaces, a line drop compensator is required
(efficiency = 75 %).
Absolute angle encoders 0.35 A (+0.085 A with line-drop compen-
sator)
a
LC 0.30 A (+0.085 A with line-drop compen-
sator)
a