January 2012 3.16 Analog PLC Inputs/Outputs 235
3.16 Analog PLC Inputs/Outputs
Specifications:
Analog inputs Voltage range: –10 V to +10 V
Input resistance: > 40 kΩ
Resolution: 10 mV
Analog outputs Voltage range: –10 V to +10 V
Load impedance: > 5 kΩ
Ουτπυτ χυρρεντ: < 2 μΑ
Resolution: 10 mV
Inputs for Pt 100
thermistors
Constant current: 4.096 mA
Temperature range: 0 °C to 100 °C
Resolution: 0.01 °C, increment: 0.03 °C
Terminals on the
PLA-H 08-04-04
The interfaces of the PLA-H 08-04-04 module are electrically separated
from the 230 V line power in accordance with EN 50178.
Sensors and external devices that are connected to the PLA-H 08-04-04
module must be supplied exclusively either with 24 V NC or with 24 V PLC.
The inputs and outputs of the module are not galvanically isolated internally.
In the HSCI system, the two supply voltages must not be connected with
each other, however.
Sensors and external devices that are connected to the PLA-H 08-04-04
module and are supplied with 24 V NC must have double basic insulation.
Properties Socket connectors on the PLA-H
08-04-04
Connection: Socket connector with tension clamp
connection, type:
X81, X82:
Weidmüller B2L 3.5/10 SN SW
2-row, 10-pin
X66, X67, X46, X47, X48, X49:
Weidmüller B2L 3.5/6 SN SW
2-row, 6-pin
Connectable conductors: Usable conductor cross sections
without wire-end sleeve:
0.08 mm
2
to 1.0 mm
2
Usable conductor cross sections with
wire-end sleeve:
0.14 mm
2
0.34 mm
2
0.5 mm
2
(only with Weidmüller PZ 6/
5 crimping pliers)