1354 HEIDENHAIN Technical Manual MANUALplus 620
MP_values
Discrete values or interpolation points for curve
Available from NCK software version: 597 110-01.
Format: Array [0..63]
Input: 0.000 to 200.000 [%]
The meaning of the parameter depends on MP_mode:
MP_mode = DISCRETE: Enter override values for a maximum
of 64 key inputs or potentiometer settings.
MP_mode = LINEAR:
MP_values has no function.
MP_mode = CURVE:
Define a curve with up to 64 interpolation points. The override
values are taken from the curve. Linear interpolation is again
effective above the last interpolation point specified.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
7.7.2 Override functions
Settings in the configuration editor MP number
System
PLC
CfgPlcOverrideS
[Key name of spindle]
minimal
maximal
source
104401
104402
104402
Channels
ChannelSettings
[Key name of machining channel]
CfgThreadSpindle
sourceOverride