1292 HEIDENHAIN Technical Manual MANUALplus 620
7.2.2 Configuring dashboards
Configuring the 
dashboard
 In the CfgDashboard parameter object, specify the configuration for each 
defined dashboard. For each dashboard you enter the key names of up to 16 
dashboard elements in the list MP_elementList. 
MP_elementList
List of dashboard elements, filled from the 
CfgDashboardElemnt pool.
Available from NCK software version: 597 110-01.
Format: Array [0...40]
Input: List of key names of dashboard elements configured under 
CfgDashboardElemnt in the sequence of arrangement.
Default: –
Access: LEVEL3
Reaction: RUN
The dashboard elements are aligned from left to right and from top to bottom. 
The index 0 defines the element at top left in the display.
Settings in the configuration editor MP number
System
DisplaySettings
CfgDashboard
[Key name of dashboard]
elementList
CfgDashboardElemnt
[Key name of the dashboard element]
dashboardpicType
attribut
entityList
CfgOemWindow
[Dashboard_1...4]
upperLeft
bottomRight
CfgGlbDispSettings
axesDisplayMode
113201
113101
113102
113103
605201
605202
604803