January 2012 3.6 Supply Voltages in the HSCI System 183
3.6.2 X90: +24 V NC output of the UxC 11x (FS)
Assignment
Load capacity
Current
consumption of the
HSCI components
Example: MANUALplus 620 configuration with UEC 11x
A PSL 130 unit is not needed for this application. The +24 V NC supply of the
UEC 11x (X90) suffices for the connected components.
Connecting termi-
nal X90
Assignment
+ +24 V (max. 3.5 A)
–0 V
Device Load capacity of 24 V NC supply (X90)
UEC 11x (FS) 3.5 A
Device Current consumption of the 24 V NC
supply
MC 6110T 1.5 A
MB 620T 1.0 A
PL 62xx
(incl. TS and TT)
0.5 A
PL 61xx 0.2 A
Device Current consumption 24 V
NC
MC 6110T 1.5 A
MB 620T 1.0 A
PL 61xx 0.2 A
Total 2.7 A < 3.5 A