1538 HEIDENHAIN Technical Manual MANUALplus 620
8.5.4 Configuring the displayed drives and directories in the file manager
Use the machine parameter MP_ncDir to define a list of drives and/or
directories, which are displayed in the file manager of the control. The drives
and paths are visible only if the user has the required access right.
In the factory default setting of the NC software, the three drives TNC:\, PLC:\
and SYS:\ are already configured through the environmental variables
%USR%, %OEM% and %SYS%. The SYS partition is reserved exclusively for
HEIDENHAIN and is not visible without the HEIDENHAIN daily password. The
PLC:\ partition only becomes visible when you enter the PLC code number
807667.
You can add further drives or directories to the list in MP_ncDir, which are to
be displayed in the folder tree after the file manager has been opened.
CfgOemPath:
MP_ncDir
List of drives and/or directories
Available from NCK software version: 597 110-01.
Format: Array [0...9]
Input: The drives and directories entered here are visible in the file
manager, provided that you have the required access rights.
The respective paths may contain NC programs or tables, for
example, floppy disk drive directories, HDR or CFR directories,
network drives, etc.
Default: [0]: %USR%\
[1]: %OEM%\
[2]: %SYS%\
Access: LEVEL3
Reaction: RESET
Settings in the configuration editor MP number
System
Paths
CfgOemPath
ncDir
CfgUserPath
ncDir